General Notes for SteelDeck Steel Joist Span:
1. Spans are based on continuous lateral support of the compression flange.
2. The joist rim must be installed according to the installation instructions.
3. Rim tab must be attached to the hard side of the joist.
4. Joist "TDJ" = 1 3/4" flange, Beam "TDW" = 2" flange.
5. FY is 33 ksi for 18-gauge, 50 ksi for 16,14, and 12-gauge.
6. 10 psf Dead Load and 40 psf Live Load
7. TL Deflection = L/360, LL Deflection = L/480
8. Max span allowable for 16" o.c. spacing - 17' 6"
9. Max span allowable for 24" o.c. spacing - 15' 3"
10. Max overhang 1' 6"

 


CODE APPROVAL
International Building Code

Section 2205, Cold Formed Steel
International Residential Code

Section R505, Steel Floor Framing